Cohort studyindependent cross-checkabstract checked I-CHM-122 standard review

Heart dose and heart attacks after breast radiotherapy: a check of Darby

Validation and Modification of a Prediction Model for Acute Cardiac Events in Patients With Breast Cancer Treated With Radiotherapy Based on Three-Dimensional Dose Distributions to Cardiac Substructures.

Overview

van den Bogaard VA et al.. J Clin Oncol 2017 · PMID 28095159 · DOI 10.1200/JCO.2016.69.8480

Risk of acute heart events rose by about 16.5% per Gy of heart dose; the typical heart dose was low (2.4 Gy).

Does the study support the specific claim? Yes · Methodological quality: moderate

Original publication

Plain-language summary

Study explained simply
What did the researchers want to find out?

Check the Darby dose-response

How was the study done?

Cohort with 3D dose data

How many people, animals or samples were studied?

910 Dutch women

What was actually found?

Dose-response confirmed

How large was the observed effect?

16.5%/Gy (0.6-35.0)

What do the results mean in everyday life?

Lower heart dose means lower risk; modern doses are low

What are the study's limitations?

Few events

What does it say about Elawady's specific claim?

Supports the 7.4%/Gy claim as relative risk

Do the results apply to Germany and Europe?

High

What can explicitly not be concluded from this study?

Does not give absolute lifetime risk

Scientific in-depth review

1. Full reference

Authors
van den Bogaard VA et al.
Journal
J Clin Oncol
Year
2017
Identifier
PMID 28095159 DOI 10.1200/JCO.2016.69.8480
Verification
verified – PubMed efetch 2026-10-26 (PublicationType and CommentsCorrections checked); Crossref 2026-10-26
Retracted
no
Corrections

ErratumIn J Clin Oncol 2017;35(32):3736 (PubMed; Crossref 10.1200/jco.2017.76.2732); no retraction

Extent checked
abstract only
Conflicts of interest and funding

Not stated in abstract.

2. Research question

Is the Darby relationship between mean heart dose and acute coronary events reproducible, and are other dose parameters better predictors?

3. Study design and population

Study design
Cohort study – Cohort study (validation of Darby model) with 3D CT-based dosimetry
Population

910 consecutive women irradiated after breast-conserving surgery

Country

Netherlands

Period

Follow-up median 7.6 years (to 10.1)

Sample size

910

Inclusion and exclusion criteria

Consecutive patients with 3D planning data

4. Methods and endpoints

Exposure / intervention

Mean heart dose and substructure doses

Comparator

Lower doses

Endpoints

Cumulative incidence of acute coronary events within 9 years

Statistical methods

Cox/NTCP modelling

5. Actual results

Results

Median mean heart dose 2.37 Gy (0.51-15.25); 30 acute coronary events; cumulative incidence increased by 16.5% per Gy (95% CI 0.6-35.0; P=.042); LV-V5 best predictor; model c-statistic 0.83.

Absolute risks

30 events in 910 patients over a median 7.6 years (about 3.3% crude)

Authors' conclusion

A significant dose-effect relationship for acute coronary events within 9 years was found; the relative increase per Gy was similar to the previous study.

6. Strengths

  • Individual 3D dosimetry
  • Modern techniques (low doses)

7. Weaknesses

  • Few events; wide CI
  • Single region

8. Risk of bias

Orienting tool
ROBINS-E
Type of assessment
simplified assessment (abstract only)
Full formal assessment
no
Overall risk of bias
some concerns
Rationale

Observational; few events.

9. Assessment of the statistical interpretation

Slope imprecise (0.6-35%/Gy). At the cohort's median mean heart dose (2.37 Gy) the implied relative increase is about 17% (Darby slope) to 39% (this slope) (stats/C-CHM-02.py).

10. Relevance to the specific claim

Replicates the Darby dose-response with modern CT-based dosimetry, supporting the 7.4%/Gy figure as a reasonable estimate (point estimate even higher, but imprecise).

11. Independent contrary findings

Taylor 2017 (I-CHM-06): absolute risk small with modern doses.

12. Transferability to Germany and Europe

Directly applicable (European cohort).

13. Overall methodological judgement

Independent replication of the dose-response.

Multidimensional assessment
Multidimensional assessment
Authenticity of the sourceverified
Methodological qualitymoderate
Risk of biassome concerns
Precision of resultslow
Directnessdirect
Reproducibilityreplicated
Consistency with the overall evidenceconsistent
Regional transferabilityhigh
Adequacy of the interpretation (by the archive)not applicable

14. Open questions

Precise slope at very low doses.

15. Linked fact checks