Otherindependent cross-checkabstract checked I-WHT-123 standard review

Common blood tests for zonulin do not actually measure zonulin

Serum zonulin as a marker of intestinal mucosal barrier function: May not be what it seems.

Overview

Ajamian M et al.. PLoS One 2019 · PMID 30640940 · DOI 10.1371/journal.pone.0210728

Analysis showed two widely used commercial zonulin tests detect other proteins (haptoglobin, complement C3).

Does the study support the specific claim? No · Methodological quality: moderate

Original publication

Plain-language summary

Study explained simply
What did the researchers want to find out?

Validate zonulin tests.

How was the study done?

Laboratory protein analysis.

How many people, animals or samples were studied?

Sera samples.

What was actually found?

Kits detect other proteins.

How large was the observed effect?

not applicable

What do the results mean in everyday life?

Be cautious with "leaky gut" zonulin claims.

What are the study's limitations?

Two kits.

What does it say about Elawady's specific claim?

Weakens extrapolation of the zonulin pathway.

Do the results apply to Germany and Europe?

High.

What can explicitly not be concluded from this study?

Does not disprove the biopsy findings.

Scientific in-depth review

1. Full reference

Authors
Ajamian M et al.
Journal
PLoS One
Year
2019
Identifier
PMID 30640940 DOI 10.1371/journal.pone.0210728 · PMC6331146
Verification
verified – PubMed efetch 2026-10-26; Crossref works API 2026-10-26
Retracted
no
Corrections
none
Extent checked
abstract only
Conflicts of interest and funding

No competing interests declared.

2. Research question

Do commercial serum zonulin assays detect zonulin?

3. Study design and population

Study design
Other – Laboratory assay validation study
Population

Patients with GI dysfunction and healthy individuals (sera)

Country

not stated in abstract

Period

not stated in abstract

Sample size

not stated in abstract

Inclusion and exclusion criteria

not stated in abstract

4. Methods and endpoints

Exposure / intervention

Commercial zonulin ELISA kits (CUSABIO; Immundiagnostik)

Comparator

Mass spectrometry identification

Endpoints

Identity of detected antigen

Statistical methods

Immunoprecipitation, mass spectrometry, SDS-PAGE

5. Actual results

Results

Commercial assays did not detect zonulin (prehaptoglobin-2): top matches were haptoglobin and complement C3 (CUSABIO) and complement C3 (Immundiagnostik).

Absolute risks

not reported

Authors' conclusion

Current commercial zonulin assays do not detect the actual protein; caution is advised when using serum zonulin as a barrier marker.

6. Strengths

  • Direct analytical test

7. Weaknesses

  • Two kits only

8. Risk of bias

Orienting tool
none applicable
Type of assessment
simplified assessment (abstract only)
Full formal assessment
no
Overall risk of bias
low
Rationale

Analytical study.

9. Assessment of the statistical interpretation

not applicable

10. Relevance to the specific claim

Many human "zonulin" findings rest on assays that do not measure zonulin, weakening extrapolation of the zonulin pathway to population health claims.

11. Independent contrary findings

Biopsy-based studies (A-WHT-16/17) did not rely on serum ELISAs.

12. Transferability to Germany and Europe

High.

13. Overall methodological judgement

Important methodological caveat.

Multidimensional assessment
Multidimensional assessment
Authenticity of the sourceverified
Methodological qualitymoderate
Risk of biaslow
Precision of resultsnot applicable
Directnessindirect
Reproducibilitypartly replicated
Consistency with the overall evidenceconsistent
Regional transferabilityhigh
Adequacy of the interpretation (by the archive)not applicable

14. Open questions

Validated assays.

15. Linked fact checks