Meta-analysisindependent cross-checkabstract checked★ key study I-LIFE-111 standard review

Slow-breathing devices for high blood pressure

Efficacy of device-guided breathing for hypertension in blinded, randomized, active-controlled trials: a meta-analysis of individual patient data.

Overview

Landman GW et al.. JAMA Intern Med 2014 · PMID 25222103 · DOI 10.1001/jamainternmed.2014.4336

When compared fairly with sham devices or music, slow-breathing devices did not lower blood pressure.

Does the study support the specific claim? No · Methodological quality: high

Original publication

Plain-language summary

Study explained simply
What did the researchers want to find out?

Test DGB for hypertension.

How was the study done?

IPD meta-analysis of blinded trials.

How many people, animals or samples were studied?

3 trials with IPD.

What was actually found?

No BP reduction.

How large was the observed effect?

SBP +2.2 mmHg (-2.7 to 7.0) favouring control.

What do the results mean in everyday life?

Breathing exercises relax, but do not replace blood pressure treatment.

What are the study's limitations?

Few trials.

What does it say about Elawady's specific claim?

Limits 'beneficial for health' to well-being.

Do the results apply to Germany and Europe?

Applies; same physiology.

What can explicitly not be concluded from this study?

Effects of other breathing techniques.

Scientific in-depth review

1. Full reference

Authors
Landman GW et al.
Journal
JAMA Intern Med
Year
2014
Identifier
PMID 25222103 DOI 10.1001/jamainternmed.2014.4336
Verification
verified – PubMed efetch 2026-10-26; Crossref update-to/updated-by check
Retracted
no
Corrections
none
Extent checked
abstract only
Conflicts of interest and funding

not stated in abstract

2. Research question

Does device-guided slow breathing lower blood pressure when compared with sham or music?

3. Study design and population

Study design
Meta-analysis – Individual patient data meta-analysis of blinded RCTs with active control
Population

Adults with hypertension

Country

International

Period

not stated in abstract

Sample size

5 eligible studies; IPD from 3

Inclusion and exclusion criteria

not stated in abstract

4. Methods and endpoints

Exposure / intervention

Device-guided breathing (>=4 weeks)

Comparator

Music therapy or sham device

Endpoints

Office blood pressure

Statistical methods

Linear mixed models

5. Actual results

Results

Office systolic BP 2.2 mmHg (95% CI -2.7 to 7.0) in favour of control; diastolic 0.2 mmHg (-2.8 to 3.1) in favour of DGB; no significant effect.

Absolute risks

not reported

Authors' conclusion

DGB did not significantly lower office blood pressure compared with sham or music; no recommendation for hypertension treatment.

6. Strengths

  • Blinded active-controlled trials only
  • IPD

7. Weaknesses

  • IPD missing for 2 of 5 trials
  • Short follow-up

8. Risk of bias

Orienting tool
AMSTAR 2
Type of assessment
simplified assessment (abstract only)
Full formal assessment
no
Overall risk of bias
some concerns
Rationale

Incomplete IPD.

9. Assessment of the statistical interpretation

Null result with CI excluding large benefits; see stats/I-LIFE-111_breathing.py.

10. Relevance to the specific claim

Limits health claims: when properly controlled, slow breathing did not lower blood pressure.

11. Independent contrary findings

12. Transferability to Germany and Europe

Universal biology; applies in Europe and Egypt.

13. Overall methodological judgement

Contradicts disease-treatment claims for breathing; not the relaxation part.

Multidimensional assessment
Multidimensional assessment
Authenticity of the sourceverified
Methodological qualityhigh
Risk of biassome concerns
Precision of resultsmoderate
Directnessdirect
Reproducibilitypartly replicated
Consistency with the overall evidenceconsistent
Regional transferabilityhigh
Adequacy of the interpretation (by the archive)not applicable

14. Open questions

15. Linked fact checks